Product Details:

  • Glass Size Standard optical glass prism
  • Measuring Range Ethylene Glycol: -60C to 0C; Propylene Glycol: -50C to 0C; Battery Fluid: 1.10 to 1.40 SG
  • Outer Size Approx. 27 mm x 160 mm
  • Display Analog scale (optical refractive reading)
  • Sensor Type Manual optical sensor
  • Case Aluminum body with rubber grip and protective plastic case
  • Material Aluminum, plastic, rubber, glass
  • Click to View more
X

Ethylene Glycol / Coolant Refractometer Price And Quantity

  • Automatic Temperature Compensation (ATC) 10°C-30°C
  • 0.2%
  • Dropper, mini screwdriver, cleaning cloth, instruction manual, plastic case
  • 2-3 drops
  • Yes, focus adjustable
  • Approx. 200 grams
  • Manual (distilled water)

Ethylene Glycol / Coolant Refractometer Product Specifications

  • Industrial, laboratory
  • Ethylene Glycol: -60C to 0C; Propylene Glycol: -50C to 0C; Battery Fluid: 1.10 to 1.40 SG
  • 0.2%
  • Standard optical glass prism
  • Manual optical sensor
  • Analog scale (optical refractive reading)
  • Approx. 27 mm x 160 mm
  • Silicone rubber
  • Aluminum, plastic, rubber, glass
  • Aluminum body with rubber grip and protective plastic case
  • Measurement of ethylene glycol, propylene glycol, and battery fluids in automotive and industrial coolant systems
  • Atmospheric pressure (manual device)
  • Automatic Temperature Compensation (ATC) 10°C-30°C
  • 0.2%
  • Dropper, mini screwdriver, cleaning cloth, instruction manual, plastic case
  • 2-3 drops
  • Yes, focus adjustable
  • Approx. 200 grams
  • Manual (distilled water)

Ethylene Glycol / Coolant Refractometer Trade Information

  • All India

Product Description

Ethylene Glycol / Coolant Refractometer

Product Details:
ApplicationIndustrial, Laboratory
we would like to introduce Hand Held or digital Urea Refractometer to check quickly and accurately measures the Ethylene Glycol / Coolant Refractometer in coolants which is used in automobile industries

Measurement range will be 0-100% with freezing point.


High Accuracy & Wide Range Measurements

This refractometer delivers accuracy up to 0.2% and supports a broad measuring rangecovering ethylene glycol from -60C to 0C, propylene glycol from -50C to 0C, and battery fluid from 1.10 to 1.40 specific gravity. Its designed for industrial and laboratory use, ensuring trust in critical automotive and coolant applications.


Automatic Temperature Compensation

Equipped with automatic temperature compensation (ATC) between 10C and 30C, this device guarantees consistent readings even when ambient temperature changes. ATC helps users avoid recalibration due to temperature fluctuations, making testing more convenient and reliable on site or in the field.


User-Friendly Manual Operation

The refractometer features a manual calibration process using distilled water, a simple sample size requirement of 2-3 drops, and a focus-adjustable eyepiece for clear readings. Its optical sensor and analog scale provide instant results, ideal for both novices and experienced technicians.

FAQs of Ethylene Glycol / Coolant Refractometer:


Q: How do I calibrate the Ethylene Glycol / Coolant Refractometer before use?

A: Calibration is straightforward; use distilled water to set the baseline. Place 23 drops onto the prism, close the cover, and adjust the calibration screw using the included mini screwdriver until the scale reads zero. This ensures accurate measurements every time.

Q: What substances can this refractometer measure, and what are the specific ranges?

A: The device is designed to measure the concentrations of ethylene glycol (-60C to 0C), propylene glycol (-50C to 0C), and the specific gravity of battery fluids (1.10 to 1.40 SG), covering a comprehensive range used in coolant and battery maintenance.

Q: When should I use the temperature compensation feature?

A: The automatic temperature compensation (ATC) is always active during operation between 10C and 30C. This feature ensures accuracy despite temperature changes, making it ideal for fieldwork and laboratory settings where temperatures may vary.

Q: Where can this refractometer be applied for best results?

A: The instrument is well-suited for use in industrial and automotive laboratories, manufacturing facilities, and on-site maintenance. Its intended for professionals needing precise measurements of coolants and battery fluids, especially in environments across India.

Q: What is the process for taking a measurement using this device?

A: Simply calibrate the device with distilled water, then clean and dry the optical glass prism. Add 23 drops of the fluid sample, close the cover, and view the analog scale through the eyepiece. The adjustable focus ensures a clear reading, and results are immediate.

Q: What are the benefits of using this manual optical refractometer?

A: It offers high accuracy, rapid results, and user-friendly operation. Its robust aluminum construction and supplied accessories enhance durability and portability, making it an essential tool for technicians and quality control teams monitoring coolant and battery systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Aerosol Food and Beverages Testing Instruments' category